Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can utilize in this gear? A: This gear to medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation material, liquid waste and gas waste. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average power.
Clover incinerator utilize time per day up to 24 hours. Between every feed/combustion period, there are approximately 0.5-1 hours cooling period and time to get feeding squander. Actual combustion time per day is about 16 hours. The life of incinerator between 5-10 year according to utilize.
Generally, we proposition little lab, little clinic use capacity under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output capacity around 2kgs per individuals per day. If there are 200 sickbed at the clinic, that’s mean you need one incinerator capacity around 400kgs per day, change to power per hour is around 30-40 kgs per hour. According the performance time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We supply all files and incinerators simple to installation and functionality. Client can send individuals visit our factory to learn installation and operation. Generally, We do not send engineer to neighborhood site or even request. The dispatch cost is extra according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD annually maintenance according model, utilize situation.
One person can service 02 device incinerators. The team should have basic electrician incinerator 50 kg, incinerator 500 kg, incinerator animal, incinerator burner, incinerator burner model for cremation croupes, incinerator catalog, incinerator combustion capacity, knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know risk of medical waste to safeguard worker self with necessary protection component.
One person can service 02 unit incinerators. The staff should have basic electrician incinerator 50 kg, incinerator 500 kg, incinerator animal, incinerator burner, incinerator burner model for cremation croupes, incinerator catalog, incinerator combustion capacity, knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |