Q: What’s kind of waste can use within this gear? A: This gear for medical waste, pet animal, Municipal waste, reside squander. Prohibit any volatile and radiation material, liquid gas and waste waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding squander. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.
Ordinarily, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output around 2kgs per people every day. If there are 200 sickbed at the clinic, that’s mean you need one incinerator capacity around 400kgs every day, switch to capacity per hour is around 30-40 kgs per hour. According the operation time every day, waste material, funding, development, etc, you can use capacity from 30-50 kgs each hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Meeting and Testing A: We provide all files and incinerators simple to installation and functionality. Client can send people visit our factory to learn operation and installation. China incinerator producer and exporter, crematorium manufacturers, double chamber incinerator, incinerator producer in china, incinerator manufacturers china, Ordinarily, we don’t send engineer to local site or even request. The dispatch cost is additional according to order. The second combustion chamber: 1000-1200 centi degree. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One individual can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and understand risk of medical waste to safeguard worker self with essential protection component.
Q: The Residency time in secondary combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |